1300 000 734

BX-SERIES BREAKOUT – RISER RATED CABLES

BX006D***9*R

  • Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary
  • Easiest cable to install where direct termination of the subcable to a connector and a direct run to panels and equipment are desired
  • Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
  • 900μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices, because connectors terminate directly to the subcable
  • High crush resistance may eliminate the need for innerduct

Availability: In stock

Contact RFI Wireless

Click on image to zoom

More Views


    FEATURES
  • High performance components and construction
  • UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
  • Most rugged and easy to install cable design for enterprise cabling applications
  • Core-Locked™ outer jacket design for installation survivability and long-term,trouble free service
  • Ideal for use in long, vertical installations
  • 2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)
  • Subcabled fiber is environmentally and mechanically protected
  • Ideal for use in point-to-point runs in adverse environments
  • Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
  • Design is ideal for direct pulling with mesh grips
  • Cable materials are indoor/outdoor - UV, water and fungus resistant
  • Wide operating temperature range of -40°C to +85°C
  • High performance 900 µm tight-buffered coating on each optical fiber for environmental and mechanical protection
  • Interlocking armor can be applied to cables as an alternative to conduit installation
  • 2 to 72 fibers




    COST SAVINGS
  • Direct termination to subcable may eliminate the need for patch panels and patch cords and reduces connector loss
  • 900 micron buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the subcable
  • No need to splice outdoor cable to indoor cable at building entrance
  • High crush resistance may eliminate the need for innerduct
Brand OCC
Fibre Name B-Series Breakout Cables
Fibre Rating Riser Rating
Fibre Type Single-Mode & Multi-Mode
Fibre Count 2 to 72
Laser Class Ultra-Fox
Tight Bauffered 900 µm tight-buffered
Impact Resistance 1500
Flex Resist 2000
Flame Retardancy UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Operating Temperature -40°C to + 85°C
Storage Temperature Range -55°C to +85°C
Primary Coating Diameter 245 µm
Secondary Buffer Diameter 900 µm
Water Resistance yes
UV resistance yes
Install Temp -10°C to +60°C
Standards UL 1651, UL 1666, GR-409-CORE, ICEA-S-104-696, ICEA-S-83-596, TIA-568, TIA-598
Diameter (mm / inches) 2.5mm, 2.0mm and 2.9mm subcables are available
Jacket Type Indoor/Outdoor PVC
Jacket Color Black

Ask a question about this product

Signupto RFI newsletter